Call Us: 858-909-9033

Quick reference guide for CPT codes for Pain Procedure Codes.

1Official DescriptionCommon DescriptionProcedure CodesPossible Additional CodesExplanationsWork RVUTotal RVU
2 HakoMed (medicare)   97016; 97032; 97112   97016; 97032; 97112

97016 - 0.18; 

97032 - 0.25; 

97112 - 0.45

97016 - 0.55; 

97032 - 0.54; 

97112 - 0.96

3 HakoMed (Work comp/ Ppo)   97014; 97112; 97016   97014; 97112; 97016

97014 - 0.18 

97112 - 0.45; 

97016 - 0.18

97014 - 0.45; 

97112 - 0.96; 

97016 - 0.55

4 Intrathecal Pump Placement   62362; 62350; 76000   62362; 62350; 76000

62362 - 5.60; 

62350 - 6.05; 

76000 - 0.17

62362 - 11.11; 

62350 - 11.52; 

76000 - 1.34

5 Intrathecal Pump Removal   62365   62365 62365 - 3.93 62365 - 8.60
6 Occipital Nerve Block   64405   64405 64405 - 0.94 64405 - 1.81
7 Occipital Nerve Stimulator - Placement   63655;a 63685; 95972   63655; 63685; 95972

63655 - 10.92; 

63685 - 5.19; 

95972 - 0.80

63655 - 24.09; 

63685 - 10.54; 

95972 - 1.19

8 Occipital Nerve Stimulator - Trial   63650; 95972   63650; 95972

63650 - 7.15; 

95972 - 0.80

63650 - 11.82; 

95972 - 1.19

9 Peripheral Nerve Stimulation - Trial   64575; 95972   64575; 95972

64575 - 4.42

95972 - 0.80

64575 - 9.22; 

95972 - 1.19

10 Peripheral Nerve Stimulator Placement, Permanent   64575; 95972   64575; 95972

64575 - 4.42

95972 - 0.80

64575 - 9.22; 

95972 - 1.65

11 Procedure - Trigger Point Injection one or two muscles   20552   20552 20552 - 0.66 20552 - 1.09
12 Procedure - Trigger Point Injection one or two muscles (WC)   20550   20550 20550 - 0.75 20550 - 1.13
13 Pump Refill, Hospital   95991; 62368; 76000   95991; 62368; 76000

95991 - 0.77; 

62368 - 0.67; 

76000 - 0.17

95991 - 1.13; 

62368 - 1.01; 

76000 - 1.34

14 Pump Refill, Office   95991; 62368; A4220; J2275   95991; 62368; A4220; J2275

95991 - 0.77; 

62368 - 0.67; 

A4220 - 0; 

J2275 - 0

95991 - 1.13; 

62368 - 1.01; 

A4220 - 0; 

J2275 - 0

15 Spinal Cord Stimulator Generator Implant - COMPLETE TREATMENT PLAN   63685 +95972 63685 - generator placement; +95972 - programming of stimulator

63685 - 5.19;

+95972 - 0.80

63685 - 10.54;

+95972 - 1.19

16 Percutaneous Spinal Cord Stimulator Permanent Lead and Generator Implant - COMPLETE TREATMENT PLAN   63560; 63685 +95972 63650 - percutaneous lead placement; 63685 - generator placement; +95972 - programming of stimulator

63560 - no RVU; 

63685 - 5.19; 

+95972 - 0.80

63560 - no RVU; 

63685 - 10.54; 

+95972 - 1.19

17 Spinal Cord Stimulator Permanent Lead and Generator Implant with Laminectomy - COMPLETE TREATMENT PLAN   63655; 63685 +95972 63655 - lead placement with laminectomy; 63685 - generator placement; +95972 - programming of stimulator

63655 - 10.92; 

63685 - 5.19; 

+95972 - 0.80

63655 - 24.09; 

63685 - 10.54; 

+95972 - 1.19

18 Spinal Cord Stimulator Removal   63660; 63688   63660 - removal of stimulator leads; 63688 - removal of generator

63660 - No RVU; 

63688 - 5.30

63660 - no RVU; 

63688 - 10.71

19 Spinal Cord Stimulator Trial, Percutaneous   63650; 63650; +95972   63650 - lead placement; +95972 - programming of stimulator

63650 - 7.15; 

63560 - no RVU; 

+95972 - 0.80

63650 - 11.82; 

63560 - no RVU; 

+95972 - 1.19

20 Spinal Cord Stimulator Trial with Laminectomy   63655; +95972   63655 - lead placement with laminectomy; +95972 - programming of stimulator

63655 - 10.92; 

+95972 - 0.80

63655 - 24.09; 

+95972 - 1.19

21 Transforaminal Epidural Steroid Injection of Lumbar Spine   64483; 72275; 77003   64483; 72275; 77003

64483 - 1.90; 

72275 - 0.76; 

77003 - 0.60

64483 - 3.21

72275 - 3.26; 

77003 - 2.66

  Spinal puncture, therapeutic, for drainage of cerebrospinal fluid (by needle or catheter)   62272   Spinal Tap, Lumbar Drain Placement 62272 - 1.35 62272 - 2.43
  Laminectomy for implantation of neurostimulator electrodes, plate/paddle, epidural   63655   63650 - percutaneous lead placement; 63685 - generator placement; +95972 - programming of stimulator 63655 - 10.92 63655 - 24.09
  Insertion or replacement of spinal neurostimulator pulse generator or receiver, direct or inductive coupling   63685   63650 - percutaneous lead placement; 63685 - generator placement; +95972 - programming of stimulator 63685 - 5.19 63685 - 10.54
  Injection(s), of diagnostic or therapeutic substance(s) (eg, anesthetic, antispasmodic, opioid, steroid, other solution), not including neurolytic substances, including needle or catheter placement, interlaminar epidural or subarachnoid, cervical or thoracic; with imaging guidance (ie, fluoroscopy or CT)   62321   cervical or thoracic epidural steroid injection 62321 - 1.95 62321 - 3.17
  Injection(s), of diagnostic or therapeutic substance(s) (eg, anesthetic, antispasmodic, opioid, steroid, other solution), not including neurolytic substances, including needle or catheter placement, interlaminar epidural or subarachnoid, lumbar or sacral (caudal); with imaging guidance (ie, fluoroscopy or CT)   62323   lumbar or sacral epidural steroid injection 62321 - 1.95 62323 - 3.17
  Revision including replacement, when performed, of spinal neurostimulator electrode percutaneous array(s), including fluoroscopy, when performed   63663     63663 - 7.75 63663 - 12.93
  Revision including replacement, when performed, of spinal neurostimulator electrode plate/paddle(s) placed via laminotomy or laminectomy, including fluoroscopy, when performed   63664     63664 - 11.52 63664 - 25.12